Industrial Connectors High Power Connectors Circular Connectors M12 System Cabling har-modular®: PCB Connectors
News Room Press & media contacts Technology magazine tec.news
How to Buy Configurators Download Manager (Download Product Data) Technical Support General supplier information
HARTING Careers

Industrial connectors / Han®


Overview
Rectangular connectors
Rectangular connectors
Industrial circular connectors
Industrial circular connectors
Connectors & cable assemblies for specific applications
Connectors & cable assemblies for specific applications

Circular connectors


Overview
Metric circular connectors
Metric circular connectors
Industrial circular connectors
Industrial circular connectors

Device connectivity


Overview
PCB connectors
PCB connectors
Panel feed throughs
Panel feed throughs
Cable connectors and cable assemblies
Cable connectors and cable assemblies

Industrial Ethernet Switches


Overview
Industrial Ethernet Switches
Industrial Ethernet Switches

Operator interfaces


Overview
Operator interfaces
Operator interfaces

Charging equipment for Electromobility


Overview
Charging equipment for Electromobility
Charging equipment for Electromobility

Tools


Overview
Tools
Tools

Cable assemblies & bulk cables


Overview
Power and signal
Power and signal
Data
Data
Bulk cables
Bulk cables

Industries


Agriculture Technologies
Industry - Agriculture Technologies Overview
Industrial Automation
Automation - Hero Image
Data Centers
Data Centers Website Touchpoint Graphic - 1200 x 628.jpg
E-Mobility Technologies
AES sector graphic MOBILITY
Energy
Energy - Grid Hero Image
Hydrogen Technologies
Hydrogen Ecosystem Overview
Machinery
Machinery Americas - Hero Image
Railway
Railway Overview
Robotics
2024-08_GettyImages-1333855916_Robotics.jpg
Semiconductor Manufacturing
SemiconductorManufacturing_Overview.tif
Smart Infrastructure
2024-09_Cooling_Heating_System_GettyImages-1002890486.jpg

Applications


Customised Solutions
HARTING customised solution
Circular connectors cable assemblies
Cable assemblies circular connectors
Review industrial ethernet connectors
Industrial Ethernet solutions
Field wireable connectors
Field installation
Single Pair Ethernet
Cable Connectors Cable Assemblies Data connectors Single Pair Ethernet
D-Sub PushPull
D-Sub PushPull connect
Solenoid systems
Solenoid systems
MID Solutions
MID Solutions

The Technology Group


About HARTING Technology Group
HQT Building, Espelkamp
The future needs the past
The Future needs the Past
The Harting family
A family-run Company
Awards & recognition
We are proud about our awards
Facts & figures
Facts and Figures

About HARTING Americas


HARTING Americas
HARTING North America
Manufactured in America
website_Elgin-production-floor.png
Industry Partnerships
Industry Partnerships

Sustainability


Our Responsibility
Our Responsibility
Our Corporate Culture
Our Corporate Culture
Our Environment
Our environment
Our Technologies
Our technologies
Our commitment to society
Our Social Commitment
Environmental Statement
Road with painted yellow arrow line
Whistleblower System
Protect by Seeing and Acting - BKMS Whistleblower System
Sustainability Certificates
CSR Certificates
Human Rights
Declarations

Quality


Integrated Management System
2024-05_GettyImages-1214111373_man woman talk tablet.jpg
Our quality claim
HQT Building, Espelkamp
Testing and Laboratories
Material analysis
Our commitment to society
Our Social Commitment
Our Environment
Our environment
Download Certificates - Integrated Management System
CSR Certificates

Customer Service


myHARTING
Website Advanced Stage
Customer Service
Customer Service
Customer Information
Customer Support - Front of HARTING plant 1 HQT
Product Change Notifications
hero_Han-Industriesteckverbinder.tif
Website Training Center
Website Training Center
Download Declarations - Product Compliance
CSR Certificates

Contact Us


Contact Us
HARTING North America
HARTING Worldwide
HARTING Worldwide - Flags

Alternatives:

Search by series
Configurators
  1. Home
  2. Wind Energy
  3. Safe signal transmission due to surge protection module

Safe signal transmission due to surge protection module

HARTING Han-Modular® Surge Protection Modules provide transient protection for common signals in the field of control and regulation technology.


Header Windenergie Blitz.tif

Due to their altitude and often exposed location on hills, ridges, etc., wind turbines are frequent targets of lightning strikes. The strike passes through the entire system and affects the components and electrical systems. However, not only direct lightning strikes, but also strikes in the immediate vicinity of the turbine and the connected supply networks can lead to malfunctions or failures of sensitive electronic components. By contrast, a consistent lightning and surge protection concept avoids expensive downtime and repairs. Thus, it contributes to a performance that allows the turbines to pay for themselves in the intended time.

For transient protection of common signals in the field of control and regulation technology HARTING has developed the Han-Modular® Surge Protection Module in cooperation with the company Dehn + Söhne, who are specialists in the field of lightning and surge protection.

In a wind turbine’s lightning protection concept, the module can be considered as the last small element in an extended arrestor system, ranging from the large arrestors on the blade and the transition points over the tower as Faraday cage to the protective devices for frequency converters, control cabinets, measuring and control equipment.

The insert is part of an entire modular connector and protects the adjacent systems or circuits from transient surges. If the transient – caused by a lightning strike or electromagnetic charges – enters the electronical system, it will already be dissipated in the connector by the Surge Protection Module within the housing. The further spread of the transient is prevented, downstream systems are protected against interference or damage.

Windenergie-und-Überspannungsschutz_0.jpg

Han-Modular® SP DM2 Modul for surge protection

The surge protection module uses several protection elements such as gas arrestors, suppressor diodes and resistors. If a transient surge occurs, the protective elements ensure a coordinated derivation of the disturbance variable.

The upstream surge protection opens up further possibilities of cost and space savings in the connected systems. In a control cabinet, for example, the applied voltage peak is derived via the connector and the switch cabinet housing. No further elements are needed to protect the control cabinet. The Surge Protection Module thus saves space and additional costs.

In wind turbine areas protected from transient surges, signals can be transmitted interference-free. Properly used, the module reduces the amount of downtime disturbances of signal communication, it prolongs the machine’s service life by improving uptime and protecting sensitive electronic devices.

HARTING System Solutions for Windenergy

Catalogues, Brochures, Flyer


HARTING Newsletter

Social Media


© HARTING Technology Group

  • Imprint
  • Privacy Policy
  • Cookie Policy
  • Terms of Use
  • Customer Information